5.2.21 Energy Meter Source
The controller can make an estimate of the energy used for a total process or, for example, for different batches in a process. This information is totalised and shown in parameters E.Par and E.tot.
P81 |
Select P81 to configure Energy Meter Source. It is necessary to define the output in which to make the energy measurement. This would normally be the output which make the biggest demand on the power, for example, the output supplying heaters. |
|
none |
Function not enabled (factory default) |
|
oP1 |
OP1 Function linked to output 1 |
|
oP2 |
OP2 Function linked to output 2. |
|
oP3 |
OP3 Function linked to output 3. |
|
oP4 |
OP4 Function linked to output 4 |
P82 |
Select P82 to enter Nominal Load Power in KW. This value is manually entered, normally when commissioning the controller, and is the rated power of the load (heater power). P82 is not shown if P81 = none. |